content loaded
ABB XT2HU3050MFF000XXX Image 1

ABB XT2HU3050MFF000XXX 50A 3-POLE FIXED CIRCUIT BREAKER

MFR Part #: XT2HU3050MFF000XXX
SKU #: 1285600
Brand: ABB
UPC: 888614406667
ABB XT2HU3050MFF000XXX Tmax XT Low Voltage Molded Case Circuit Breaker, 600/690 VAC, 50 A, 25 kA Interrupt, 3 Poles, Thermal Magnetic/Electronic Trip
For all distribution levels from the main low voltage switchboard to the sub-switchboards in the installation
UL Listed | CSA Certified | IEC Certified

ABB, XT2HU3050MFF000XXX, Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600/690 VAC, 50 A, 50/60 Hz Frequency, 25 kA Interrupt, XT2 125A Frame, Thermal Magnetic/Electronic Trip, 150 to 550 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3.54 in W x 3.25 in D Dimensions

Tmax XT molded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety.

Product Details

ABB, XT2HU3050MFF000XXX, Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600/690 VAC, 50 A, 50/60 Hz Frequency, 25 kA Interrupt, XT2 125A Frame, Thermal Magnetic/Electronic Trip, 150 to 550 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3.54 in W x 3.25 in D Dimensions

Tmax XT molded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety.

Attributes

Amperage Rating50 A
Connection TypeFront Line/Load Side
Country Of OriginITALY
Number of Poles3
Dimensions5.12 in H x 3.54 in W x 3.25 in D
FrameXT2 125A
Frequency Rating50/60 Hz
Insulation TypeDouble Insulated
Interrupt Rating25 kA
SeriesTmax XT
Temperature Rating-13 to 158 deg F
Trip Range150 to 550 A
Trip TypeThermal Magnetic/Electronic
TypeLow Voltage
Voltage Rating600/690 VAC

Features

  • Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
  • F front terminals, no lugs installed on line and load side termination (top/bottom)
  • Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
  • A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
  • XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
  • Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
  • Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
  • Motor circuit protector trip unit