ABB XT2NU3050AFF000XXX Image 1

ABB XT2NU3050AFF000XXX XT2N 125 TMF 50-500A 3-POLE FF BREAKER

MFR Part #: XT2NU3050AFF000XXX
SKU #: 1272143
Brand: ABB
UPC: 888614403253
ABB XT2NU3050AFF000XXX Tmax XT Low Voltage Molded Case Circuit Breaker, 600/690 VAC, 50 A, 18 kA Interrupt, 3 Poles, Electronic/Fixed Thermal Magnetic Trip
For all distribution levels from the main low voltage switchboard to the sub-switchboards in the installation applications
UL Listed | CSA Certified | IEC Certified

ABB Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600/690 VAC, 50 A, 50/60 Hz Frequency, 18 kA Interrupt, XT2 125A Frame, Electronic/Fixed Thermal Magnetic Trip, 50 to 500 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3.54 in W x 3.25 in D Dimensions

Tmax XT molded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety.

Product Details

ABB Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600/690 VAC, 50 A, 50/60 Hz Frequency, 18 kA Interrupt, XT2 125A Frame, Electronic/Fixed Thermal Magnetic Trip, 50 to 500 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3.54 in W x 3.25 in D Dimensions

Tmax XT molded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety.

Attributes

Amperage Rating50 A
Country Of OriginITALY
Number of Poles3
Voltage Rating600/690 VAC
Connection TypeFront Line/Load Side
Dimensions5.12 in H x 3.54 in W x 3.25 in D
FrameXT2 125A
Frequency Rating50/60 Hz
Insulation TypeDouble Insulated
Interrupt Rating18 kA
SeriesTmax XT
Temperature Rating-13 to 158 deg F
Trip Range50 to 500 A
Trip TypeElectronic/Fixed Thermal Magnetic
TypeLow Voltage

Features

  • Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
  • XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
  • A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
  • Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
  • Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
  • Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
  • F front terminals, no lugs installed on line and load side termination (top/bottom)
  • 18 kA normal breaking capacity