content loaded
LUMACELL RG12S1002MT9W Image 1
COO Canada

LUMACELL RG12S100/2MT9W EMERGENCY LTG PACK /W 2 9W HEADS

MFR Part #: RG12S1002MT9W
SKU #: 1086869
Brand: ABB | Lumacell®
UPC: 624616036132
Lumacell® Nexus® RG12S1002MT9W Battery Unit, 9 W Mini Tungsten Lamp, 120/347 VAC, 12 VDC, 2 Heads, Steel
This product may be subject to ecological fees.
Institutional, Industrial, Commercial and Hospitality Applications
CSA C22.2 File No. 141-15

Lumacell® Nexus® Battery Unit, Series: RG12S, 120/347 VAC, 12 VDC, 100 W Fixture, 0.12/0.34 A, 60 Hz Frequency, Mini Tungsten Lamp, 9 W Lamp, 2 Heads, Lead Calcium Battery Power Source, NEMA 4X Enclosure, Wall Mounting, 13-1/4 in W x 5-1/2 in D x 16-1/2 in H Dimensions, Steel, White

The RGS series battery units combine long life expectancy, high performance design and a reasonable initial cost outlay. Ideally suited for a range of commercial applications, the long life lead-acid battery is specifically recommended for environments where the unit will be exposed to large variances in ambient temperature. The Lumacell® Smart diagnostic micro-controller board shall supply the rated load for a minimum of a 1/2 hr to 87.5% of the rated battery voltage. The unit shall be rated 120/347 VAC , 60 Hz and be CSA listed. The unit shall have an output of: V and W. The charger shall be fully computer tested and its charge voltage factory set to +/- 1% tolerance. Chargers with field-adjusted potentiometers are not acceptable. A pulse-type charger shall be employed to promote long battery life and reduce the potential for grid corrosion. The charger shall provide a continuous high charge to recharge the battery, when the battery is at full capacity, the charger will shut-off. Periodically the charger shall provide a pulse of energy to keep the battery topped off. The pulse charger shall be precisely regulated and shall charge the battery in relation to its temperature, state or charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short circuit proof and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit, which will connect the battery when the AC circuit is activated and an electronic brownout circuit, which will activate the emergency lights when utility power dips below 75% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load when the battery reaches the end of discharge. The unit shall self test for 1 minute every 30 days, 10 min on the 6th month and 30 min every 12 months. The unit shall be capable of full recharge in compliance with CSA specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and diagnostic LED indicator lights to continuously monitor the status of the unit: battery Failure, battery disconnected, charger failure, lamp failure, service alarm, AC "ON", charger high Rate. The emergency lighting heads shall require no tools for orientation.

Product Details

Lumacell® Nexus® Battery Unit, Series: RG12S, 120/347 VAC, 12 VDC, 100 W Fixture, 0.12/0.34 A, 60 Hz Frequency, Mini Tungsten Lamp, 9 W Lamp, 2 Heads, Lead Calcium Battery Power Source, NEMA 4X Enclosure, Wall Mounting, 13-1/4 in W x 5-1/2 in D x 16-1/2 in H Dimensions, Steel, White

The RGS series battery units combine long life expectancy, high performance design and a reasonable initial cost outlay. Ideally suited for a range of commercial applications, the long life lead-acid battery is specifically recommended for environments where the unit will be exposed to large variances in ambient temperature. The Lumacell® Smart diagnostic micro-controller board shall supply the rated load for a minimum of a 1/2 hr to 87.5% of the rated battery voltage. The unit shall be rated 120/347 VAC , 60 Hz and be CSA listed. The unit shall have an output of: V and W. The charger shall be fully computer tested and its charge voltage factory set to +/- 1% tolerance. Chargers with field-adjusted potentiometers are not acceptable. A pulse-type charger shall be employed to promote long battery life and reduce the potential for grid corrosion. The charger shall provide a continuous high charge to recharge the battery, when the battery is at full capacity, the charger will shut-off. Periodically the charger shall provide a pulse of energy to keep the battery topped off. The pulse charger shall be precisely regulated and shall charge the battery in relation to its temperature, state or charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short circuit proof and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit, which will connect the battery when the AC circuit is activated and an electronic brownout circuit, which will activate the emergency lights when utility power dips below 75% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load when the battery reaches the end of discharge. The unit shall self test for 1 minute every 30 days, 10 min on the 6th month and 30 min every 12 months. The unit shall be capable of full recharge in compliance with CSA specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and diagnostic LED indicator lights to continuously monitor the status of the unit: battery Failure, battery disconnected, charger failure, lamp failure, service alarm, AC "ON", charger high Rate. The emergency lighting heads shall require no tools for orientation.

Attributes

Country Of Origin: Canada
Dimensions: 13-1/4 in W x 5-1/2 in D x 16-1/2 in H
Series: RG12S
Amperage Rating: 0.12/0.34 A
Color: White
Enclosure Type: NEMA 4X
Fixture Wattage: 100 W
Frequency Rating: 60 Hz
Lamp Type: Mini Tungsten
Lamp Wattage: 9 W
Material: Steel
Mounting Type: Wall
Number of Heads: 2
Power Source: Lead Calcium Battery
Voltage Rating: 120 to 347 VAC/12 VDC

Features

  • Rugged steel cabinet with corrosion-resistant undercoating
  • Removable front panel on cabinet provides easy access and allows the unit to be mounted at ceiling height
  • Solid state pulse-type charger current limited, temperature compensated, short circuit proof and reverse polarity protected
  • Unit comes standard with electronic lockout and brownout circuits
  • Sealed dust-proof transfer relay, test switch and LED indicator lights
  • Long life, maintenance free lead-acid battery
  • Standard 120/347 VAC input voltage with line cord kit
  • Round head
  • Lead batteries
  • Rugged steel material