content loaded
GOODMAN GMES960805CN Image 1

GOODMAN GMES960805CN FER UF FURNACE

MFR Part #: GMES960805CN
SKU #: 1219258
Brand: Goodman®
UPC: 978721
Goodman® GMES960805CN Gas Furnace, 80000 Btu/hr Input BTU, 115 VAC, 2000 cu-ft/min, 1 hp at 1075 rev/min, 96% AFUE
10 Year Parts and Unit Replacement, Limited Lifetime on Heat Exchanger
AHRI Certified, ETL Listed, ISO 9001 and 14001

Goodman® Gas Furnace, GMES96 Model, 80000 Btu/hr Input BTU Rating, 115 VAC, 11.7 A, 2000 cu-ft/min, 1 hp at 1075 rev/min, 96% AFUE, 1 -Phase, 60 Hz, Configuration: Upflow/Horizontal, 1/2 in FPT Gas Connection, Low Nox Fuel, 4 -Burner, 5 -Speed, 10 in W x 11 in Dia Blower Size, 21 in W x 34-1/2 in H x 28-7/8 in D Cabinet Dimensions, Upflow/Horizontal Motor, 2 - 3 in Vent, 15 A Fuse, 5 ton, Heavy Gauge Steel, 25 - 55 deg F Rise

Product Details

Goodman® Gas Furnace, GMES96 Model, 80000 Btu/hr Input BTU Rating, 115 VAC, 11.7 A, 2000 cu-ft/min, 1 hp at 1075 rev/min, 96% AFUE, 1 -Phase, 60 Hz, Configuration: Upflow/Horizontal, 1/2 in FPT Gas Connection, Low Nox Fuel, 4 -Burner, 5 -Speed, 10 in W x 11 in Dia Blower Size, 21 in W x 34-1/2 in H x 28-7/8 in D Cabinet Dimensions, Upflow/Horizontal Motor, 2 - 3 in Vent, 15 A Fuse, 5 ton, Heavy Gauge Steel, 25 - 55 deg F Rise

Attributes

AFUE Rating96 %
Amperage Rating11.7 A
Blower Size11 in Dia x 10 in W
Cabinet Dimensions21 in W x 28-7/8 in D x 34-1/2 in H
CFM Rating2000 cfm
ConfigurationUpflow/Horizontal
Connection Type1/2 in FPT Gas
Frequency Rating60 Hz
Fuel TypeLow Nox
Fuse Rating15 A
HP Rating1 hp at 1075 rpm
Input BTU Rating80000 Btu/hr
MaterialHeavy Gauge Steel
ModelGMES96
Motor TypeUpflow/Horizontal
Number of Burners4
Number of Speeds5
Phase1 ph
Temperature Rise25 to 55 deg F
Tonnage5 ton
Vent Size2 to 3 in
Voltage Rating115 VAC

Features

  • Heavy-duty aluminized steel tubular heat exchanger
  • Stainless steel secondary heat exchanger
  • Single-stage gas valve
  • Durable silicon nitride igniter
  • Quiet, single-speed draft induced
  • Self-diagnostic control board with constant memory fault code history output to a LED
  • All models comply with California 40 ng/J Low NOx emissions standard
  • Easy-to-install top venting with optional side venting - GMES96/upflow models only
  • Convenient left or right connection for gas and electrical service
  • Cabinet air leakage (QLeak) less than 2%
  • Heavy-gauge steel cabinet with durable finish
  • Fully insulated heat exchanger and blower section
  • Airtight solid bottom for side return with easy cut tabs for effortless removal in bottom air inlet applications