TACO 0011-F4-2IFC 1/8HP CAST IRON CIRCULATOR WITH INTERNAL FLOW CHECK LESS FLANGE

MFR Part #: 0011-F4-2IFC
SKU #: 1019513
Brand: Taco® Comfort Solutions™
UPC: 687752556100
Taco® 0011-F4-2IFC 00 Cast Iron Cartridge Circulator, 30 gpm Flow Rate, 3/4, 1-1/4, 1, 1-1/2 in Inlet x 3/4, 1-1/4, 1, 1-1/2 in Outlet, 115 V, 1 Phase , Domestic
3 Years
For Radiant Heating Systems, Domestic Water Systems, Chilled Water Cooling, Zoning with Circulators, Hydro-Air Fan Coils and Hydronic Heating System
UL Listed

Taco®, 0011-F4-2IFC, Cartridge Circulator, Cast Iron, Series: 00, 30 gpm Flow Rate, 3/4, 1-1/4, 1, 1-1/2 in Inlet, 3/4, 1-1/4, 1, 1-1/2 in Outlet, 31 ft Maximum Head, 1/8 hp Power, 115 V, 1.76 A, 60 Hz Frequency, 1 ph, 150 psi Maximum, 3250 rpm Motor, Non-Metallic Impeller, Flange Mounting, 40 to 220 deg F, Carbon Bearing, 6-1/2 in H x 5-1/2 in W x 7-1/2 in D Dimensions, Domestic

The 0011-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00® circulators. Typical uses include large residential or light commercial high head / medium flow applications such as hydronic or radiant heating, hydro-air fan coils, indirect water heaters or domestic water recirculation systems. By locating the removable, spring-loaded IFC inside the pump casing, a separate in-line flow check is eliminated. The reduced pressure drop of the IFC increases the 0011 flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit.

Product Details

Taco®, 0011-F4-2IFC, Cartridge Circulator, Cast Iron, Series: 00, 30 gpm Flow Rate, 3/4, 1-1/4, 1, 1-1/2 in Inlet, 3/4, 1-1/4, 1, 1-1/2 in Outlet, 31 ft Maximum Head, 1/8 hp Power, 115 V, 1.76 A, 60 Hz Frequency, 1 ph, 150 psi Maximum, 3250 rpm Motor, Non-Metallic Impeller, Flange Mounting, 40 to 220 deg F, Carbon Bearing, 6-1/2 in H x 5-1/2 in W x 7-1/2 in D Dimensions, Domestic

The 0011-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00® circulators. Typical uses include large residential or light commercial high head / medium flow applications such as hydronic or radiant heating, hydro-air fan coils, indirect water heaters or domestic water recirculation systems. By locating the removable, spring-loaded IFC inside the pump casing, a separate in-line flow check is eliminated. The reduced pressure drop of the IFC increases the 0011 flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit.

Attributes

Country Of OriginUS
Flow Rate30 gpm
HP Rating1/8 hp
Maximum Head31 ft
Voltage Rating115 V
Amperage Rating1.76 A
Bearing TypeCarbon
Dimensions6-1/2 in H x 5-1/2 in W x 7-1/2 in D
Domestic/ImportDomestic
Frequency Rating60 Hz
Impeller TypeNon-Metallic
Inlet Size3/4, 1-1/4, 1, 1-1/2 in
Maximum Pressure150 psi
Motor Speed3250 rpm
Mounting TypeFlange
Outlet Size3/4, 1-1/4, 1, 1-1/2 in
Phase1
Power Rating1/8 hp
Series00
Temperature Rating40 to 220 deg F
TypeCast Iron

Features

  • Compact Design
  • Eliminates Separate In-Line Flow Check
  • Integral Flow Check
  • Direct Drive Low Power Consumption
  • Field Serviceable
  • Prevents Gravity Flow/Reverse Flow
  • Self-lubricating and no mechanical seal to replace
  • Unmatched Reliability Maintenance Free