VICTAULIC V014786CBV 786 1-1/2IN SLDR BALANCING VALVE

MFR Part #: V014786CBV
SKU #: 1063356
Brand: Victaulic®
Victaulic® V014786CBV 786 Balancing Valve, 1-1/2 in Nominal, Solder End Style, 66 gpm Flow Rate, AMETAL® Body

Victaulic® Balancing Valve, Series: 786, 1-1/2 in Nominal, Solder End Style, 300 psi Pressure, -4 to 250 deg F, 66 gpm Flow Rate, Media: Water, Handwheel Actuator, 5.13 in Inlet to Outlet Length, 4-3/4 in Top to Inlet Center, AMETAL® Body, Metal Trim, EPDM Seat, Seal Softgoods, 1.9 in OD Dimensions

Tour and Anderson calibrated balancing valves offer a reliable, simple and cost effective way to measure and balance all flow rates. Full throttling range is achieved by 4, 8, 12, 16, 20 or 22 full turns of the handwheel, enabling a precise setting. This high degree of accurate adjustment means that the system can be balanced precisely. The actual pressure drops in heating and cooling systems are difficult to establish by calculation because water flows vary from design flows. They can be corrected easily by regulating the desired water flow with Tour & Anderson globe style balancing valves. By measuring the pressure drop across measuring ports at a particular handwheel setting, the water flow for the valve size can be read easily from the appropriate pressure drop graph or flow balancing wheel. If the flow does not conform with that specified, adjust the valve and repeat the measuring procedure until the correct flow has been obtained.

Product Details

Victaulic® Balancing Valve, Series: 786, 1-1/2 in Nominal, Solder End Style, 300 psi Pressure, -4 to 250 deg F, 66 gpm Flow Rate, Media: Water, Handwheel Actuator, 5.13 in Inlet to Outlet Length, 4-3/4 in Top to Inlet Center, AMETAL® Body, Metal Trim, EPDM Seat, Seal Softgoods, 1.9 in OD Dimensions

Tour and Anderson calibrated balancing valves offer a reliable, simple and cost effective way to measure and balance all flow rates. Full throttling range is achieved by 4, 8, 12, 16, 20 or 22 full turns of the handwheel, enabling a precise setting. This high degree of accurate adjustment means that the system can be balanced precisely. The actual pressure drops in heating and cooling systems are difficult to establish by calculation because water flows vary from design flows. They can be corrected easily by regulating the desired water flow with Tour & Anderson globe style balancing valves. By measuring the pressure drop across measuring ports at a particular handwheel setting, the water flow for the valve size can be read easily from the appropriate pressure drop graph or flow balancing wheel. If the flow does not conform with that specified, adjust the valve and repeat the measuring procedure until the correct flow has been obtained.

Attributes

Actuator TypeHandwheel
Body MaterialAMETAL®
Dimensions1.9 in OD
End StyleSolder
Flow Rate66 gpm
Inlet to Outlet Length5.13 in
MediaWater
Nominal Size1-1/2 in
Pressure Rating300 psi
Series786
Softgoods MaterialEPDM Seat, Seal
Temperature Rating-4 to 250 deg F
Top to Inlet Center4-3/4 in
Trim MaterialMetal

Features

  • "Y" patterned globe valve