MODINE PDP250AE130 Image 1

MODINE PDP250AE0130SBAN 250MBH PROPELLER UNIT HEATER

MFR Part #: PDP250AE130
SKU #: 1111095
Brand: MODINE
UPC: 046629437155
MODINE PDP250AE130 Propeller Unit Heater, 115 V, 7.75 A, 250000 Btu/hr BTU, 1 ph-Phase, Steel
10 Year
For commercial applications
ANSI Z83.8 Specified | CSA Certified | ETL Listed | UL Listed

MODINE Propeller Unit Heater, 250000 Btu/hr, 115 V, 7.75 A, 1053 fpm, 3700 cfm CFM Rating, 1/3 hp HP Rating, 1 ph, 60 Hz, NPT, 1/2 in, Liquid Propane Gas, Natural Gas, 20 in Fan Size, 83 % Efficiency, PSC Motor, 1075 rpm Rotational Speed, Intermittent Pilot Ignition, 1 Stage, 19 ft Mounting Height, 67 ft Heat Throw, Steel, Baked-On Polyester Powder-Coated, 50 deg F, 40-1/4 in H x 25-5/8 in W x 34-3/4 in D

Product Details

MODINE Propeller Unit Heater, 250000 Btu/hr, 115 V, 7.75 A, 1053 fpm, 3700 cfm CFM Rating, 1/3 hp HP Rating, 1 ph, 60 Hz, NPT, 1/2 in, Liquid Propane Gas, Natural Gas, 20 in Fan Size, 83 % Efficiency, PSC Motor, 1075 rpm Rotational Speed, Intermittent Pilot Ignition, 1 Stage, 19 ft Mounting Height, 67 ft Heat Throw, Steel, Baked-On Polyester Powder-Coated, 50 deg F, 40-1/4 in H x 25-5/8 in W x 34-3/4 in D

Attributes

Amperage Rating7.75 A
BTU Rating250000 Btu/hr
CFM Rating3700 cfm
Connection Size1/2 in
Connection TypeNPT
Dimensions40-1/4 in H x 25-5/8 in W x 34-3/4 in D
Efficiency83 %
Fan Size20 in
FinishBaked-On Polyester Powder-Coated
Flow Rate1053 fpm
Frequency Rating60 Hz
Fuel TypeLiquid Propane Gas, Natural Gas
Heat Throw67 ft
HP Rating1/3 hp
Ignition TypeIntermittent Pilot
MaterialSteel
Motor TypePSC
Mounting Height19 ft
Number of Stages1
Phase1 ph
Rotational Speed1075 rpm
Temperature Rating50 deg F
Voltage Rating115 V

Features

  • 80% thermal efficiency, maximizing seasonal efficiency through the use of a collector box and the power exhauster
  • A power exhaust that can be rotated 180 deg, the unit can be vented vertically or horizontally
  • A 100% shut-off, intermittent pilot-ignition system with continuous retry, at no extra charge, this ignition system allows for all PDP/BDP units to be field converted to propane, if desired
  • A safety pressure switch to assure safe venting conditions
  • Designed to utilize the smallest diameter vent pipe possible
  • Wing screws so that the bottom pan can be dropped without a screwdriver or nut driver
  • A levels hanging mechanism for easy field adjustments after adding accessories that may change the unit's center of gravity
  • Aluminized steel heat exchanger or burner
  • A automatic reset vent pressure switch is supplied on all power vented unit heaters to prevent operation of the main burner in the event there is restricted venting of flue products
  • All power vented unit heaters are supplied with a round vent pipe connection, power exhauster may be rotated 180 deg to allow for various venting directions