content loaded
EATON BR340 Image 4

EATON BR340 BR 40A 3-POLE 10KAIC THERMAL MAGNETIC CIRCUIT BREAKER

MFR Part #: BR340
SKU #: 0711130
Brand: EATON
UPC: 786676367851
EATON BR340 Type BR Circuit Breaker, 240 V AC, 40 A, 10 kA Interrupt, 3 Poles, Thermal Magnetic Trip
10 years
Conventional Energy Generation, Renewable Energy and Alternative Energy Generation, Marine Vessels and Equipment, Type BR Loadcenters and Circuit Protection Applications
Federal Specification W-C-375 | PROP65: This product can expose you to chemicals including Nickel compounds, which is known to the State of California to cause cancer and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. | UL 489

EATON Circuit Breaker, Type BR, 240 V AC, 40 A, 10 kA Interrupt, Thermal Magnetic Trip, 3 Pole, 1 ph, 14 to 4 AWG Wire, NEMA 1/4X/3R, Plug-On Mount, 600 to 750 deg C, 3 in L x 3 in W x 3 in H

Eatons BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.

Product Details

EATON Circuit Breaker, Type BR, 240 V AC, 40 A, 10 kA Interrupt, Thermal Magnetic Trip, 3 Pole, 1 ph, 14 to 4 AWG Wire, NEMA 1/4X/3R, Plug-On Mount, 600 to 750 deg C, 3 in L x 3 in W x 3 in H

Eatons BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.

Attributes

Amperage Rating40 A
Country Of OriginDominican Republic
Mounting TypePlug-On
Number of Poles3
Voltage Rating240 V AC
Dimensions3 in L x 3 in W x 3 in H
Enclosure TypeNEMA 1/4X/3R
Interrupt Rating10 kA
Phase1
Temperature Rating600 to 750 deg C
Trip TypeThermal Magnetic
TypeType BR
Wire Size14 to 4 AWG

Features

  • and AF/GF designs
  • Short-body design maximizes your space inside the loadcenter
  • creating additional wire-way and gutter space for ease of installation
  • Easy to read trip codes through improved LEDs and a clear test button increases your troubleshooting efficiency
  • Improved AFCI and GFCI algorithms significantly reduce nuisance tripping
  • resulting in less call backs