content loaded
SQUARE D QO120CAFI Image 1

SQUARE D QO120CAFI 1 POLE ARC FAULT 20 AMP PLUG-IN BREAKER

MFR Part #: QO120CAFI
SKU #: 1134968
Brand: Square D™
UPC: 785901438359
Square D™ QO120CAFI Combination Miniature Arc Fault Circuit Breaker, 120 VAC, 20 A, 10 kA Interrupt, 1 Poles, K-Curve/Thermal Magnetic Trip
For providing overload and short circuit protection designed to detect arc faults
Buy American Act Compliant | CSA 22.2 #5 | RoHS Compliant | UL 489 | PROP65: This product can expose you to chemicals including: Lead and Lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov

Square D™, QO120CAFI, Combination Miniature Arc Fault Circuit Breaker, 120 VAC, 20 A, 50/60 Hz Frequency, 10 kA Interrupt, QO/100 A Frame, K-Curve/Thermal Magnetic Trip, 1 Pole, 1 ph, Pressure Plate Connection, 12 to 8 AWG, 14 to 8 AWG Wire, Plug-On Mounting, 104 deg F, 2.91 in L x 0.75 in W x 4.75 in H Dimensions

QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a combination arc fault with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.

Product Details

Square D™, QO120CAFI, Combination Miniature Arc Fault Circuit Breaker, 120 VAC, 20 A, 50/60 Hz Frequency, 10 kA Interrupt, QO/100 A Frame, K-Curve/Thermal Magnetic Trip, 1 Pole, 1 ph, Pressure Plate Connection, 12 to 8 AWG, 14 to 8 AWG Wire, Plug-On Mounting, 104 deg F, 2.91 in L x 0.75 in W x 4.75 in H Dimensions

QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a combination arc fault with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.

Attributes

Amperage Rating20 A
Country Of OriginMexico
Mounting TypePlug-On, Plug-In
Number of Poles1
Actuator TypePaddle
Connection TypePressure Plate
Dimensions2.91 in L x 0.75 in W x 4.75 in H
FrameQO/100 A
Frame TypeQO
Frequency Rating50/60 Hz
Height2.91 in
Interrupt Rating10 kA
Length4.76 in
Phase1, 1 ph
SeriesQO™ Series
Temperature Rating40 deg C, 104 deg F
Terminal TypePigtail Neutral
Trip TypeThermal Magnetic, K-Curve/Thermal Magnetic
Voltage Rating120 VAC, 120/240 VAC
Width3/4 in
Wire Size14 to 8 AWG, 12 to 8 AWG, 14 to 8 AWG

Features

  • An arc fault circuit breaker opens the circuit and stops the arcing and high intensity heat before a fire is likely to ignite
  • Special microprocessor based arc identification to differentiate necessary operational arcs (associated with loads such as electric motors, switches and receptacles) from actual arc faults which can cause damage and fires
  • Differentiate true arc faults from chopped wave-forms associated with switched mode power supplies on electrical appliances, computers and lamp dimmers
  • 14 - 8 AWG copper, 12 - 8 AWG aluminum
  • Have special microprocessor-based arc identification to differentiate necessary operational arcs (associated with loads such as electric motors, switches and receptacles) from actual arc faults which can cause damage and fires
  • K-Curve trip
  • Combination ARC fault