SQUARE D QO250GFI Image 1

SQUARE D QO250GFI PUSH-IN 2-50 AMP GROUND FAULT

MFR Part #: QO250GFI
SKU #: 0715171
Brand: Square D™
UPC: 785901764861
Square D™ QO250GFI Class A Ground Fault Miniature Circuit Breaker, 120/240 VAC, 50 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
For providing overload and short circuit protection designed to offer class A ground fault protection for people
Buy American Act Compliant | RoHS Compliant | UL 489 | CSA 22.2 #144 | PROP65: Cancer and Reproductive harm - www.P65warnings.ca.gov

Square D™, QO250GFI, Miniature Circuit Breaker, Class A Ground Fault, 120/240 VAC, 50 A, 50/60 Hz Frequency, 10 kA Interrupt, QO Frame, Thermal Magnetic Trip, 2 Pole, 1 ph, Box Lug Connection, 14 to 6 AWG, 12 to 4 AWG Wire, Plug-On Mounting, 40 deg C, 2.91 in L x 1.5 in W x 4.12 in H Dimensions

QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 50A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.

Product Details

Square D™, QO250GFI, Miniature Circuit Breaker, Class A Ground Fault, 120/240 VAC, 50 A, 50/60 Hz Frequency, 10 kA Interrupt, QO Frame, Thermal Magnetic Trip, 2 Pole, 1 ph, Box Lug Connection, 14 to 6 AWG, 12 to 4 AWG Wire, Plug-On Mounting, 40 deg C, 2.91 in L x 1.5 in W x 4.12 in H Dimensions

QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 50A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.

Attributes

Amperage Rating50 A
Connection TypeBox Lug
Country Of OriginMexico
Number of Poles2
Dimensions2.91 in L x 1.5 in W x 4.12 in H
FrameQO
Frequency Rating50/60 Hz
Interrupt Rating10 kA
Mounting TypePlug-On
Phase1
Temperature Rating40 deg C
Trip TypeThermal Magnetic
TypeClass A Ground Fault
Voltage Rating120/240 VAC
Wire Size14 to 6 AWG, 12 to 4 AWG

Features

  • Qwik-Gard® GFCIs provide the same branch circuit protection as standard QO™ circuit breakers
  • They are longer than standard QO™ circuit breakers and thus require more gutter space
  • Class A devices must trip at 6 mA of ground fault current and above and hold below 4 mA of ground fault current
  • For use with QO™ load centers, NQOD panel boards/interiors and Speed-D® switchboard distribution panels
  • 14 to 6 AWG Cu, 12 to 4 AWG Al wire
  • Common trip
  • Ground fault protecting class A 6 mA