content loaded
FUSES KLLU1200 Image 1

1200A 600V CLASS L TIME DELAY FUSES KLLU1200

MFR Part #:Ā KLLU1200
SKU #:Ā 1030960
Brand:Ā LittelfuseĀ®
UPC:Ā 079458271065
LittelfuseĀ® POWR-GARDĀ® KLLU1200 Current Limiting Time Delay Fuse, 1200 A, 600 V AC/300 V DC, 20/200 kA Interrupt, L Class, Cartridge Body
Service Switches, Switchboard Mains and Feeders, Motor Control Center Mains, Large Motor Branch Circuits and Circuit Breaker Protection Applications
UL E81895 | CSA LR29862 | PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer

LittelfuseĀ® POWR-GARDĀ® Time Delay Fuse, Current Limiting, Series: KLLU, Non-Indicating, 1200 A, 600 V AC/300 V DC, 20/200 kA Interrupt, Class: L, Knife Blade Terminal, Bolt Mounting, Cartridge Body, Melamine, 2-1/2 in Dia x 10-3/4 in L Body

KLLU series UL Listed, time delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PROĀ® KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PROĀ® KLPC series fuses are the recommended fuses.

Product Details

LittelfuseĀ® POWR-GARDĀ® Time Delay Fuse, Current Limiting, Series: KLLU, Non-Indicating, 1200 A, 600 V AC/300 V DC, 20/200 kA Interrupt, Class: L, Knife Blade Terminal, Bolt Mounting, Cartridge Body, Melamine, 2-1/2 in Dia x 10-3/4 in L Body

KLLU series UL Listed, time delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PROĀ® KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PROĀ® KLPC series fuses are the recommended fuses.

Attributes

Body Size:Ā 2-1/2 in Dia x 10-3/4 in L
Body Type:Ā Cartridge
Country Of Origin:Ā Mexico
Interrupt Rating:Ā 20/200 kA
Material:Ā Melamine
Mounting Type:Ā Bolt
Series:Ā KLLU
Terminal Type:Ā Knife Blade
Type:Ā Current Limiting
Voltage Rating:Ā 600 V AC/300 V DC

Features

  • Current limiting - reduces short circuit damage to systems and equipment and reduced downtime
  • Easily coordinated with other system components
  • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads
  • Selective coordination - KLLU fuses coordinate well with other class L fuses and with all current-limiting LittelfuseĀ® fuses rated 600 A or less
  • Reduced downtime
  • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers
  • Although fuse/circuit breaker systems can seldom be 100 percent coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting class L fuses
  • Excellent protection for a single breaker or a group of breakers
  • 200 kA at 600 VAC, 20 kA at 300 VDC interrupting rating