content loaded
LOCHINVAR EPC199N Image 1

LOCHINVAR EPC199N EPC FRE TBE CNDSNG CMBI BOILER 199000 BTU

MFR Part #:Ā EPC199N
SKU #:Ā 1207250
Brand:Ā LochinvarĀ®
UPC:Ā 937056
LochinvarĀ® EPC199N Combination Fire Tube Gas Boiler, 95 % AFUE, 199000 Btu/hr BTU, 120 VAC, 1 ph Phase, Stainless Steel
10 Year Limited
For residential
AHRI Certified | ASME Specified | CSA Certified | ENERGY STARĀ® Certified

Lochinvar® Combination Fire Tube Gas Boiler, 120 VAC, 60 Hz Frequency, 1 ph, 95 % AFUE, 199000 Btu/hr BTU, 8.2 to 10.6 gpm Flow Rate, 50 psi Pressure, 1 in Water, 1/2 in Gas, 3 in Air Inlet Connection, Natural Gas Fuel, Horizontal Direct, Vertical Vent, Low Nox, Modulating Burner, Chimney/Breeching/Vent Size: 3 in, 185 MBtu/hr DOE Heating, Direct Spark Ignition, Net BTU Rating: 161 MBtu/hr, 161 MBtu/hr Net IBR, Wall Mounting, Stainless Steel, 77 deg F, Dimensions: 18-3/4 in L x 18 in W x 32-1/2 in H

Product Details

Lochinvar® Combination Fire Tube Gas Boiler, 120 VAC, 60 Hz Frequency, 1 ph, 95 % AFUE, 199000 Btu/hr BTU, 8.2 to 10.6 gpm Flow Rate, 50 psi Pressure, 1 in Water, 1/2 in Gas, 3 in Air Inlet Connection, Natural Gas Fuel, Horizontal Direct, Vertical Vent, Low Nox, Modulating Burner, Chimney/Breeching/Vent Size: 3 in, 185 MBtu/hr DOE Heating, Direct Spark Ignition, Net BTU Rating: 161 MBtu/hr, 161 MBtu/hr Net IBR, Wall Mounting, Stainless Steel, 77 deg F, Dimensions: 18-3/4 in L x 18 in W x 32-1/2 in H

Attributes

AFUE Rating:Ā 95 %
BTU Rating:Ā 199000 Btu/hr
Burner Type:Ā Low Nox, Modulating
Chimney/Breeching/Vent Size:Ā 3 in
Connection Type:Ā 1 in Water, 1/2 in Gas, 3 in Air Inlet
Dimensions:Ā 18-3/4 in L x 18 in W x 32-1/2 in H
DOE Heating Capacity:Ā 185 MBtu/hr
Flow Rate:Ā 8.2 to 10.6 gpm
Frequency Rating:Ā 60 Hz
Fuel Type:Ā Natural Gas
Ignition Type:Ā Direct Spark
Material:Ā Stainless Steel
Mounting Type:Ā Wall
Net BTU Rating:Ā 161 MBtu/hr
Net IBR Rating:Ā 161 MBtu/hr
Phase:Ā 1 ph
Pressure Rating:Ā 50 psi
Temperature Rating:Ā 77 deg F
Vent Type:Ā Horizontal Direct, Vertical
Voltage Rating:Ā 120 VAC

Features

  • Smart control digital operating control LCD display with words not codes
  • Outdoor reset control with outdoor air sensor
  • Programmable system efficiency optimizers DHW response time, DHW pre-heat and outdoor air reset curve
  • 2-pump control system pump and boiler pump
  • Low voltage terminal strip air handler interlock, flow switch contacts, Low water cutoff connection, system sensor contacts outdoor air sensor contacts and cascade contacts
  • Time clock for data logging last 10 lockouts
  • Low water flow safety control and indication
  • Password security
  • Built-in cascading sequencer for up to 8 units